Matsumoto S-71 STEM kit · logbook entry 27 October 1997
A kit for repeating, in a supervised school lab, the single-pulse underwater
discharge that Dr Takaaki Matsumoto recorded in logbook entry S-71: a 1 mm wire just
touching a potassium hydroxide solution inside a five-sided copper box, hit with one burst
of 120 V AC.
Design package, not a product. It has not been built, bench-tested or
certified. Read the safety section before building or using any of it.
Kickstarter coming soon… The first campaign pays to build
prototypes, test them on the bench and have an independent laboratory repeat the experiment with blanks and
controls, and publishes everything. Kits would be a second campaign.
The question is for you to investigate. Two laboratories, working within a few years of each
other on opposite sides of the world, reported new elements in what was left after an intense electrical pulse, and
both called it a collapse: Matsumoto in Sapporo with a wire, a copper box and 120 V, reporting carbon tubes from
lead and cadmium wires in what he called “the carbon-free device” (ISBL'97), and
Proton-21 in Kyiv, from 1999, with a half-million-volt electron beam on pure metals
(Results in Physics, 2015). Both argued that electromagnetic force can do in the
laboratory what gravity does in a collapsing star. We repeated Matsumoto's shot in 2025, and our SEM/EDX analysis
found carbon and other common elements where they were not present before. None of this is accepted by mainstream
physics. The Kyiv results were examined by outside experts, but not repeated on another laboratory's own
apparatus. We repeated Matsumoto's S-71 independently: he had died, and we have never met the Kyiv team. Our own
result has not yet been repeated by a laboratory independent of us, with blanks and controls. For our result the
open question is where the carbon came from. That is why controls matter, and why this kit exists: so others can test it.
Inspect our SEM images, then see step 10 of the procedure.
The cell: clip-on cap, glass vessel, copper box anode.
01
Overview
The original experiment
In run S-71 a lead wire, 1 mm across and about 180 mm long, was the cathode. The
anode was a copper box, 25 × 25 × 30 mm, with five faces (top, front,
left, right, bottom), the back open and a hole in the top. The electrolyte was KOH at
1.5 mol/L. One pulse of 120 V AC, started at phase angle 0, was applied for 800 ms.
The logbook notes: the effect of a long pulse is small; the effect of the initial surge is
marked, and the sketch shows a ball at the tip of the wire after the discharge.
What the kit is
A clip-on cell that fits over a rectangular glass vessel, and a pulse unit built around an
isolating transformer, two SCRs and three timers. It reproduces the apparatus and the
conditions, with changes made for a classroom: 55 V and 110 V levels behind a teacher's
key, one shot per press followed by a 24 s lock-out, and aluminium, iron or tin wire instead of lead.
The two pieces
The cell
A cap clips onto the vessel by six sprung fingers (about 3 N of grip, so it lifts off upward
rather than letting pressure build). The wire drops through a clamp tower, a guide tube and a
second guide just above the box. The copper box slides into rails on a carrier hanging from the
cap, and its strap bolts to an anode stud. A pointer on the carrier marks both the electrolyte
fill level and the height to set the wire tip. Gas, steam and droplets leave through a baffled
vent that faces away from the operator and has a slot for a copper witness strip, as Matsumoto
used “monitoring plates” above the water.
The pulse unit
Mains inlet, 80 VA isolating toroid, 12 V supply module, control board, and a relay
that connects the output sockets only for 1.6 s around each shot and only while the cap
interlock is closed. A teacher's key switch selects 55 V / OFF / 110 V (centre off). There is no
microcontroller and no firmware.
02
The source material
Logbook page S-71 (27 Oct 1997). Select to view at full resolution. The red box at the foot lists three dates in 1998, among them ICCF-7 (Vancouver) in April: see the videos below.
Conditions in S-70, S-71 and S-72
From the logbook page and Ref. 71 (table 1).
Parameter
S-70
S-71
S-72
Wire (cathode)
Pb, 1 mm
Pb, 1 mm, about 180 mm long
Pb, 1 mm
Electrolyte
KOH 1.5 mol/L
KOH 1.5 mol/L
Cs2CO3 0.6 mol/L
Anode
Cu box
Cu box 25 × 25 × 30 mm, five faces (T, F, L, R, B), back open, hole in top
Cu box
Drive
pulsed AC 120 V
pulsed AC 120 V, started at phase angle 0
pulsed AC 120 V
ON time
80 ms
800 ms
20 ms
Shots
4
1
5
Sapporo is on 50 Hz mains, so 20 / 80 / 800 ms are exactly 1 / 4 / 40 mains
cycles. The logbook gives the OFF time as 20 s; the table in Ref. 71 prints
20 ms for all three runs. That could not be resolved from the documents, and it
does not matter for single shots.
Our replication, 2025 · What elements can you make?
SEM deep-zoom image of our replication
We repeated S-71 in 2025. Our SEM/EDX analysis after the shot found carbon and other common elements
where they were not present before. This scanning-electron-microscope mosaic is the evidence: pan and zoom,
look at what is on the surfaces, and ask what else could explain it. Lead shows white, the pure copper base
mid-grey, and carbon and other light elements black; as we read it, the black material comes out of the lead
balls, or from smaller balls bursting out of the large ones, which leave smeared lead marks on the copper.
Not accepted by mainstream physics. Our replication was independent of Matsumoto and of Kyiv. No laboratory
independent of us has repeated it yet, and the open question is where the carbon came from (the lead,
carbonate in the electrolyte, a film on the wire, or handling). Opens in a new tab.
The plates. Two of the three copper plates from our 2025 replication of S-71, on the electron microscope's sample holder (our own photograph, taken with the microscope's navigation camera). The round marks are where the main shock of the pulse discharge acted on each plate, with knock-on effects around them.
Scanning electron micrographs published by Matsumoto in “Photographs of Electro-Nuclear
Collapse” (his collected papers, figs. 16, 17, 20 and 24). Sample codes beginning 71 are from run S-71; dates
are printed on each image. Captions in quotation marks are his own. Our 2025 image is in the card above: both show
carbon-bearing material at lead balls, as each author reports it; compare them for yourself. Neither is accepted by
mainstream physics.
Fig. 16. “Eruption of hollow Pb ball from itonic Pb ball … The mechanisms of eruption could resemble pop-corns.” Sample 71RBE (S-71), 10 Nov 1997.Fig. 17 (a). “Eruption of hollow Pb ball from itonic Pb ball”. Sample 71BBG (S-71), 30 Oct 1997.Fig. 20 (a). “Eruption of C film from hollow Pb ball”. Sample 71BDB (S-71), 28 Oct 1997.Fig. 24 (b). “Generation of C films … 71BBF: Containing Fe”. Sample 71BBF (S-71), 30 Oct 1997.
Videos
Original 1997 recording. The S-71 experiment as recorded in 1997.
Watch on YouTube
Matsumoto at ICCF-7, 1998. Dr Takaaki Matsumoto's talk at the 7th International Conference on Cold Fusion (ICCF-7), Vancouver, 23 April 1998. The red box at the foot of the logbook page lists ICCF-7 (Vancouver), April 1998. In the talk he describes these underwater spark discharge experiments and shows at least one electron-microscope picture from S-71.
Watch on YouTube
Slow motion. Replication attempt, 4 kfps, 120 V AC 50 Hz for 250 ms.
Watch on YouTube
Videos are embedded from youtube-nocookie.com and load only when you press play.
The 250 ms of the replication can be set on the kit by fitting 330k for R15 (the 80 ms position becomes 250 ms).
Sources
T. Matsumoto, experimental logbook, entry S-71, 27 October 1997 (page shown above). Its SEM/EDX notes list carbon and oxygen (“C, O”).
T. Matsumoto, presentation at ICCF-7, the 7th International Conference on Cold Fusion, Vancouver, 23 April 1998.
Recording published on YouTube by the Martin Fleischmann Memorial Project as “Matsumoto - First ever presentation
available online - ICCF-7, 1998”: youtu.be/5Vrnh25omDo.
The red box at the foot of the S-71 logbook page lists ICCF-7 (Vancouver), April 1998. Described on this page from the recording.
T. Matsumoto, “Ball Lightning during Underwater Spark Discharges and the Matsumae Earthquakes”,
ISBL'97 (1997), section 2.2(c): “Figure 6 shows examples of the carbon tube, which was produced with the Pb
and Cd wire electrodes, respectively. … this tube was generated with the carbon-free device.” The same
section reports a thin film on a copper monitoring plate during DC discharges with a Cd wire cathode.
T. Matsumoto, “Comments on ‘Evidence of Micrometre-Sized Plasmoid Emission During Electrolysis Cold Fusion’”, letter, Fusion Science and Technology 40, 108–109 (July 2001). Quoted above: “Very amazingly, it was also found later that the ring products consisted of
conventional elements, mainly carbon, not dependent on collapsed materials. This process was called nuclear
regeneration.” The letter is about ring traces from his 1992 electrolysis experiment (Fusion Technol. 22, 281), not about S-71.
Copy shared by the project (Google Drive).
T. Matsumoto, Steps to the Discovery of Electro-Nuclear Collapse: Collected Papers (1989–1999),
Hokkaido University, preface dated 5 January 2000: “Since electromagnetic force is about 40 orders stronger than
gravitational force, it should be easy to induce similar nuclear collapses by electromagnetic force in the
laboratory. … Furthermore, very amazingly, materials completely broken by ENC were found to have been
regenerated again into thin tubes and films of conventional elements such as carbon, oxygen and iron.”
This is his own general summary, not a statement about S-71 alone.
S. Adamenko, A. Esaulov, B. Ulmen et al. (15 authors, including George Miley of the University of Illinois), “Exploring new frontiers in the
pulsed power laboratory: Recent progress”, Results in Physics 5 (2015) 62–68, open access
(CC BY-NC-ND): doi.org/10.1016/j.rinp.2015.02.005.
Experiments at the IVR-1 facility in Kiev; GDMS by Evans Analytical Group found 11 of 25 elements looked for.
The authors write that they “have demonstrated in experiments that these elements are generated”, and
also that the process “may be feasible in a laboratory environment, although further a systematic study
… is required”. The paper does not cite Matsumoto.
S. Adamenko, F. Selleri, A. van der Merwe (eds), Controlled Nucleosynthesis: Breakthroughs in Experiment
and Theory, Springer, 2007 (Fundamental Theories of Physics 156):
publisher's page.
Cited by title only; not checked against its text.
Proton-21 Electrodynamics Laboratory, “Results of experiments on collective nuclear reactions in superdense
substance”, booklet, Kyiv, 2004: experiments “in 1999–2004”; “From 1999 till 2004 more
than 6000 dynamic compressions of solid targets were performed”; 15,298 analyses of about 800 samples.
Statement of the International Scientific Workshop “Kyiv Experiments on Low-Energy Nuclear Synthesis”,
Bonn, 6–7 February 2004, signed by seven participants including Proton-21's chief researcher. It opens
“As the Ukrainian physicists believe”.
D. Avau, R. Van Grieken, R. Coussement, M. Hinoul, “Conclusions verification program of nuclear
transformation experiments on samples of ‘PROTON-21’ laboratory”, Brussels, 27 February 2008.
Verification shots in Kiev, 14–17 October 2007, 99.999 % copper; starting material, blanks and fired
samples analysed in Belgian and German laboratories by SEM, EDX, AES and TOF-SIMS. Organised by Intellect
Technologies LLC, a Ukrainian-Belgian enterprise working with Proton-21; shots on Proton-21's own machine; a
signed report, not a journal paper; annexes not seen.
D. R. Welch et al., “Dynamics of the super pinch electron beam and fusion energy perspective”,
Phys. Rev. Accel. Beams 24, 120401 (2021): the beam work in the United States (abstract read). It
does not report new elements.
None of these results is accepted by mainstream physics. The Kyiv results were examined by outside experts,
but not repeated on another laboratory's own apparatus. Our 2025 replication of S-71 was independent of
Matsumoto and of Kyiv; no laboratory independent of us has repeated it yet.
Ref. 59 and Ref. 71, cited in the conditions table and the safety notes, are papers supplied with the project documents.
Yu. N. Bazhutov, A. I. Gerasimova, V. P. Koretsky and A. G. Parkhomov, international patent application WO 2015/108434 A1 (PCT/RU2014/000019), “Method and device for producing thermal energy by plasma electrolysis”, published 23 July 2015: patents.google.com/patent/WO2015108434A1. Cited only for its rule on immersion depth; see The initial surge.
Replication, 2025: video and SEM deep-zoom images linked on this page.
03
Interactive 3D
Drag to orbit; pinch, or hold Ctrl (Cmd on a Mac) and scroll, to zoom. Pull the explode slider to separate the
parts; hover, tap or pick a part from the list to see what it is for.
Loading the 3D viewer…
In motion
Rendered clips of the CAD design (not photographs; the kit has not been built). They play when on screen; use the button to pause.
04
The kit, part by part
Rendered views of the design. On annotated views, select a numbered marker to see the part's name and purpose.
The cell
Control board
Pulse unit
05
Building it
Read the safety notes. Decide who the competent adult is for the mains wiring.
Measure your glass vessel, edit CAD/params.json if it differs from 105 × 85 × 80 mm, and run python3 CAD/build_cad.py. Print the seven parts in PETG, or ASA/ABS (not PLA).
Build the control board (stripboard or PCB).
Assemble the case and wire the chassis.
Run every commissioning test, in order, before any electrolyte goes near it.
Cut and fold a copper box from the template (print at 100 %, check the 50 mm bar).
Electronics assembly
Chassis assembly
Making a copper box
Cell assembly
06
Running S-71
Ten steps. Steps marked T are for the teacher only.
Experimental layout
Pictures of the full bench setup are loading or not available.
1TTeacher only.
Key at OFF and removed, mains off. Safety screen between the cell and the class.
2TTeacher only.
Make up the electrolyte and fill the vessel until the surface just touches the pointer tip (about 97 mL for the reference vessel).
3
Slide a new copper box into the carrier rails, bring the strap up to the stud and tighten the thumb nut.
4
Cut 116 mm of 1 mm wire and straighten it. Feed it down through the clamp tower until the tip is level with the pointer tip, tighten both clamp screws, fit the red hood.
5
Clip the cap onto the vessel. Plug in the interlock jack, then the red and black leads. With aluminium or tin wire, decide the pulse settings and the level before this step, then go through steps 6 to 8 without pausing: the electrolyte starts to attack the tip as soon as it touches. Note the time from cap on to FIRE. The order stays the same, so every connection is still made before the mains goes on.
6
Mains on. POWER and CAP OK light. Select 800 ms and AC.
7TTeacher only.
Turn the key to 55 V for a first look, or 110 V for the S-71 condition.
8
Everyone behind the screen, goggles on. Press FIRE once. The buzzer (if fitted) sounds for 1.6 s, PULSE and OUTPUT flash.
9T
WAIT stays lit for 24 s. Teacher: key to OFF and out, mains off, before anyone touches the cell.
10
Lift the cap straight up, rinse the wire and box, and examine the wire tip and the inside of the box under a microscope. Slide the witness strip out of the vent.
This is where you look for an answer to what elements can you make? A light microscope
shows shape and deposits; telling which elements are present needs element analysis (such as SEM/EDX).
Compare with our SEM images, and plan controls that separate
contamination from anything new: for example a run without a pulse, a fresh box, and the wire and electrolyte as supplied.
What students record
The wire length before and after.
The shape of the tip.
Where deposits land in the box.
High-frame-rate phone video through the glass.
The difference between 55 V and 110 V, 20 ms and 800 ms, AC and rectified.
07
Safety
This kit puts a mains-powered pulse source next to a corrosive liquid and makes a
small electrical explosion on purpose. The design reduces the risks; it does not remove them, and
nobody has built or tested it yet.
Not certified
No CE/UKCA/UL assessment, no IEC 61010-1 type test. Treat it as home-built equipment: its own written risk assessment, an electrical inspection and test by a competent person, and whatever the school's science-safety adviser (CLEAPSS in the UK) requires.
Mains wiring is an adult job
Students can build the 12 V control board, print parts and fold copper. They must not wire or open the mains side.
Teacher demonstration first
Run it as a demonstration behind a safety screen. Student operation of FIRE, under supervision, is a decision for the school's risk assessment.
What was changed from the original, and why
Asked for
What was designed
Reason
Rectifier or AC divider straight from 110/230 V mains
Safety isolating transformer; nothing on the output side is connected to mains or earth
With a mains-referenced output, one hand on the electrolyte and one on a tap is a mains shock. No divider fixes that.
120 V on the cell
55 V and 110 V levels, the higher one behind a key
55 V is already above the 40 V at which Matsumoto reports sparks (Ref. 59). Start there.
Lead wire
Aluminium, iron or tin for class use; pure tungsten as an option, prepared by the teacher
An arc on lead makes lead fume and scatters lead particles. Lead belongs in a fume cupboard with an adult, not in a classroom. Aluminium and tin bring their own, smaller hazard: see “Aluminium and tin wire in alkali” below. For tungsten see “Tungsten wire (option)”.
KOH 1.5 mol/L
KOH for teacher-prepared runs; K2CO3 1.5 mol/L as the class alternative
1.5 mol/L KOH is corrosive and blinds on eye contact. Matsumoto himself used potassium carbonate in Ref. 59; it is an irritant, not a corrosive.
Hazards and the controls built in
Hazard
Control in the design
What people must still do
Electric shock from the output (55/110 V, several amps)
Isolating transformer: output floats. Output relay connects the sockets only for 1.6 s per shot. Cap interlock: relay cannot close unless the cap is on the glass. Shrouded 4 mm safety sockets and leads. Wire clamp screws recessed; red hood over the wire end. Key switch OFF isolates the transformer secondary.
Never defeat the interlock. Key out before touching the cell. Red and black leads no longer than 1 m, undamaged (the 12 V interlock lead may be up to 1.2 m).
Electric shock from the mains
Fused, double-pole switched IEC inlet. Class II 12 V module. Earthed metalwork. Plastic case with finger-safe 3 mm vents. Printed walls separate the transformer bay from the control board, and the mains inlet and 12 V module from the isolated-side parts.
Adult build, inspected and tested (below). Use an RCD-protected socket. Unplug before opening.
SCR fails short-circuit (their usual failure)
The relay is a second, independent switch, driven by a hardware timer, so the worst case is one 1.6 s burst per press. OUTPUT lamp sits before the relay: lit at rest means a fault. Nothing indicates a welded relay contact directly; it shows only as about 15 V at the sockets at rest (test 10).
If OUTPUT is lit when nobody is firing: switch off, do not use.
Controller misfires at switch-on or from noise
Power-on reset holds the timer for 0.4 s. Pulse timer is held in reset except during the relay window. Both opto LEDs in series. No firmware anywhere.
–
Caustic splash
Cap covers the vessel. Vent is baffled and faces away from the operator. Only about 100 mL of solution.
Splash-proof goggles (not safety spectacles or ordinary glasses), safety screen, teacher makes up and disposes of solution, eyewash to hand.
Bang, ejected droplets, glass
Energy per shot is capped at roughly 110 J by ballast and timer in normal operation. If an SCR has failed short, the relay window sets the limit instead: one burst of up to 1.6 s, roughly 220-270 J. The vent is always open. The cap is held by friction only and lifts at well under 0.01 bar.
Safety screen. Inspect the glass for chips and cracks before each session. Soda-lime staining troughs are not rated for thermal shock: one shot, then let it rest.
Hydrogen and oxygen
At most about 0.7 mL of mixed gas per shot into about 450 mL of vented headspace, far below the flammable limit. An aluminium or tin wire also gives off a little hydrogen while its tip is in the solution, with or without a pulse: only the tip is wetted, and the rate is still to be measured in the stage 1 bench tests.
Do not block the vent. Do not tape the cap down. Keep the time from putting the cap on to FIRE short, and lift the cap off after the shot. With aluminium, the no-pulse blank matters more: the tip changes even without a pulse.
Hot parts, overheating
Ballast on an aluminium plate with a 70 °C thermal switch in the interlock chain. 24 s lock-out between shots.
–
Metal fume and dust
–
No lead, cadmium, beryllium-copper or thoriated tungsten. Ventilated room. Wash hands.
Aluminium and tin wire in alkali
Aluminium dissolves in potassium hydroxide solution and gives off hydrogen
(2 Al + 2 KOH + 6 H2O → 2 K[Al(OH)4] + 3 H2). Potassium carbonate solution is less alkaline
but still attacks it, more slowly. Tin is also attacked by strong alkali, slowly when cold.
Iron is not. This is ordinary textbook chemistry; how fast it goes at the wire tip in our two
electrolytes has not been measured.
Why it stays small. Only the tip of the wire touches the liquid, so very little metal is exposed. By calculation, each millimetre of 1 mm aluminium wire that dissolves completely gives about 3 mL of hydrogen. Hydrogen's lower flammable limit (4 %) in 450 mL of headspace is about 18 mL, and the headspace is vented. Keep the vent clear (the hydrogen row above).
No delay. The wire touches the solution from the moment the cap goes on. Keep the time from then to FIRE as short as the procedure allows, and write it down. Lift the cap off after the shot. Do not leave aluminium or tin wire standing in the solution, and do not drop offcuts into it.
The tip changes with no pulse at all. Aluminium dulls, roughens and may bubble as soon as it touches the solution, so the no-pulse (soak) blank matters more for aluminium than for iron: hold it in the solution for the same time as a real run, in the same electrolyte.
Heat. The reaction gives out heat. At a wire tip this is negligible; with powder, foil or a long immersed length it is not, so do not use aluminium in any other form.
To confirm in the stage 1 bench tests: how fast the tip is attacked in 1.5 mol/L KOH and in 1.5 mol/L K2CO3, and whether gas at the tip affects contact before the pulse. Until then these are expectations, not measurements.
Tungsten wire (option)
Pure tungsten wire, 1.0 mm, may be used in place of the three class-use wires. It is not supplied in
the kit. The practical source is a pack of pure tungsten welding electrodes, 1.0 × 150 mm, marked WP
(green band), each cut to 116 mm. None of this has been tried on the kit: confirm it in the stage 1 bench tests.
Pure tungsten only. Buy wire or rod sold as pure tungsten (99.9 % or better). If you use welding electrodes as the source, only the pure type (marked WP, green band) will do. Never use thoriated electrodes (WT, red, yellow, purple or orange band): they contain radioactive thorium. Ceriated, lanthanated and zirconiated types are not pure tungsten either.
Cutting is a teacher's job. Tungsten is hard and brittle. Side cutters shatter it and throw sharp fragments. Notch it with a diamond file or an abrasive wheel and snap it inside a folded cloth, wearing eye protection, away from students. The cut end is sharp. Do not try to bend it.
In the electrolyte. Cold alkali attacks tungsten only very slowly with no current, so unlike aluminium there is no hurry between fitting the cap and FIRE. While current flows, alkaline electrolyte etches tungsten: this is the ordinary way tungsten probe tips are sharpened, so a thinned or pointed tip after a shot is expected electrochemistry.
Fume and deposits. An arc on tungsten gives a little tungsten oxide. It is far less hazardous than lead fume, but keep the same screen, vent and goggles, and treat deposits as samples, not dust.
Disposal. Used solution from tungsten runs contains tungstate: do not wash it away; use the school's metal waste route.
Numbers behind those claims (estimates, to be measured on the first unit)
Transformer 80 VA, 2 × 55 V: about 61 V per winding off load. Internal resistance referred to the secondary roughly 16.6 Ω (series) or 4.1 Ω (parallel), from the maker's typical regulation of 11 %.
With the 10 Ω ballast: short-circuit current about 4.6 A at 110 V and 4.3 A at 55 V.
Most power the cell can ever take: about 140 W (110 V) or 66 W (55 V). Over 0.8 s that is at most about 110 J, enough to boil off roughly 0.04 g of water (about 70 mL of steam).
With a shorted SCR the burst lasts the whole 1.6 s relay window: roughly twice the energy and charge above.
Charge per shot at most 3.7 C: about 0.5 mL hydrogen plus 0.2 mL oxygen.
Commissioning tests
Do all of them, in this order, and write down the results. Ticks are kept in this browser only; print the page for a paper record.
Only then use electrolyte, starting at 55 V and 20 ms.
Routine checks before each session
Leads and plugs undamaged; glass free of chips; vent clear; CAP OK goes out when the cap is
lifted; OUTPUT lamp dark at rest; key in the teacher's pocket.
Disposal
Neutralise used KOH or K2CO3 with dilute citric or ethanoic acid to pH 6-9 and
wash away with plenty of water, unless the solution contains anything other than copper, aluminium, iron
or tin, in which case follow the school's heavy-metal waste route. Solution used with aluminium wire may turn
cloudy white as it is neutralised (aluminium hydroxide); that is expected. Keep used wires and boxes dry in
labelled bags for microscopy.
08
How it works
How the kit reproduces the original
Original
Kit
Why
120 V AC pulse from the mains
110 V nominal (about 119-123 V off load) from an isolating transformer, plus a 55 V “first trials” level
Nothing connected to a live mains conductor can be made safe on an open electrolyte cell in a classroom. The transformer also handles 110 V and 230 V countries with one build-time wiring choice.
Pulse gated at phase angle 0
Two inverse-parallel SCRs fired by zero-crossing opto-triacs
Starts at a zero crossing and stops at a current zero, so only whole half-cycles are delivered.
800 / 80 / 20 ms
555 timer, selectable 800 / 80 / 20 ms
See the limits below.
One shot
One shot per press of FIRE, then a 24 s lock-out
Matches the logbook's 20 s OFF.
Open dish on the bench
Clip-on cap over a rectangular glass vessel, vented upward and backward, with an interlock switch
Keeps fingers and faces away from the electrolyte and the live parts.
Pb wire
Aluminium, iron or tin wire for class use; pure tungsten as an option
Arcing lead makes lead fume. Aluminium (and, slowly, tin) is attacked by the alkaline electrolyte: keep the time from putting the cap on to FIRE short, and lift the cap off after the shot. See the safety section.
“AC pulse”
AC by default; a switch selects full-wave rectified pulses (wire always negative)
Follow the power schematic from left to right. Mains comes in through the IEC inlet X1, with its
double-pole switch and fuse F1, and goes only to the transformer's primaries and the 12 V module.
The isolating transformer T1 has two 55 V windings. The teacher's key switch SW1 joins them for 55 V
or 110 V, or disconnects them (OFF). From there the output runs through fuse F2 and the ballast RB to the
SCR switch on the control board, then through the AC/DC mode switch SW2 (and, at DC, the bridge BR1) and
the relay contacts K1a and K1b to the BOX and WIRE sockets. The table describes the parts that limit,
steer and guard this path, and the earthing of the metal inside the case. To see where each one sits,
select it in the 3D model of the pulse unit.
Part
What it is
What it does, and why
Where it sits
RB, ballast resistor
10 Ω, 50 W, aluminium-clad (Arcol HS50 type), 72.5 × 28 mm with its tags.
In series with the output, between F2 and the control board. With the transformer's own resistance it limits the current into a dead short to about 4.6 A at 110 V, and so caps the energy of each shot. The 50 W rating assumes a large heatsink; this plate is much smaller, which the design files judge fine for one pulse of up to 0.8 s every 24 s. Its temperature is to be measured at commissioning test 14.
On the aluminium plate, beside TS1. Its solder tags are covered with heat-shrink sleeving.
Connected all the time across SW_OUT and AC_B, the output side of the SCR switch. An SCR stays on only while enough current flows through it: RK gives the SCRs a small steady load, so they stay latched when the discharge current is low, and it stops the relay closing from false-triggering them. It also bleeds the output. It turns about 3 W into heat while the key is on. Do not leave it out.
On the aluminium plate, beside BR1.
BR1, bridge rectifier
KBPC1006: single-phase bridge, 10 A, 600 V, 28.6 mm square case, 6.3 mm push-on tabs.
Used only when the mode switch SW2 is at DC: it turns both half-cycles of the pulse the same way, so the wire is always negative. At AC the pulse goes straight past it. Its AC inputs are joined to SW_OUT and AC_B, so it is always part of the isolated output circuit. Its metal case must be insulated from its terminals (2500 V or more), because it is bolted to the earthed plate.
On the aluminium plate, held by one M5 screw through its centre hole. Its tabs take fully insulated push-on connectors.
TS1, thermal switch
KSD301 bimetal thermostat, normally closed: opens at 70 °C, closes again at about 55 °C.
Not in the output at all. It sits in the 12 V interlock chain, in series with the cap microswitch and the relay coil. If the plate and the ballast get too hot, it opens: the relay cannot close and the unit cannot fire until it has cooled. It guards against an overheated ballast.
On the aluminium plate, beside RB, so it feels the ballast's heat.
Earth point, with ring tags
A screw stud through the plate, with serrated lock washers, crimped ring tags on the green/yellow earth wires, and a protective-earth symbol label.
The earth wire from the inlet's earth pin is fixed here. The same protective earth goes to the toroid's mounting bolt and washer and to the metal bodies of the key switch and the AC/DC toggle. If a loose mains wire touched any of this metal, the fault current would go to earth and blow a fuse or trip the RCD, instead of leaving the metal live. Commissioning test 6 checks it: under 0.1 Ω from the inlet earth pin to each part.
On the aluminium plate, next to BR1.
Aluminium plate
Aluminium sheet, 58 × 118 × 2 mm, on four 10 mm posts.
The heat spreader for RB, RK, BR1 and TS1, with heat-sink compound under each. It is metal you could touch with the lid off, so it is earthed. It is not part of the circuit: no circuit current flows through it.
Front right of the case, on the isolated-output side of the printed barrier, away from the mains inlet.
What is earthed, and what is deliberately not. Earthed, through the inlet's earth pin:
the aluminium plate, the toroid's bolt and washer, and the metal bodies of the key switch and the AC/DC
toggle. Not earthed, on purpose: the whole isolated output circuit. The transformer's secondaries, F2, RB,
RK, BR1's terminals, the SCRs, the relay contacts and the BOX and WIRE sockets float: nothing on the output
side is connected to mains or to earth. So a hand on one output terminal and the other on an earthed tap
does not complete a circuit through you. A hand on both output terminals still would, which is why the relay,
the cap interlock and the shrouded sockets are there. RB, RK and BR1 are bolted to the earthed plate by
their metal bodies, which must be insulated from their live terminals; TS1 is on the plate too, but it
carries only the 12 V interlock.
The firing sequence
Pressing FIRE starts the sequence below. There is no microcontroller and no firmware.
Lock-out (WAIT)24 s
Relay window1.6 s
Pulse T0.11 s + T
Bars to scale over 24 s, with T = 800 ms.
Time
What happens
Part
0
FIRE pulls node X low; a 1 ms pulse triggers the lock-out timer. BOUT goes high for 24 s. Further presses are ignored.
U1, R3, C3
0
W goes high (W = BOUT while the window capacitor is below VCC/3). Q2 energises relay K1 through the interlock chain; the pulse timer is released from reset.
U2b, R6, C6, Q2
0.11 s
The relay has settled. Comparator U2c trips and triggers the pulse timer. If the interlock is open there is no edge here, so no trigger.
R11, C11, U2c
0.11 s to 0.11 s + T
AOUT is high for T = 20, 80 or 800 ms. Both opto LEDs light; each SCR is gated at its own zero crossings.
U3, U4, U5, SCR1, SCR2
1.6 s
Window ends: relay opens (no current is flowing), pulse timer forced back into reset.
U2b
24 s
Lock-out ends. WAIT goes out.
U1
Calculated timings. Lock-out 1.1 × 220k × 100 µF = 24 s.
Window 330k × 10 µF × ln(10.3 / 6.4) = about 1.6 s.
Pre-delay 100k × 1 µF × ln 3 = 0.11 s.
Pulse 1.1 × R × 1 µF with R = 750k, 750k||82k, 750k||18k7 = 825, 81, 20 ms.
Electrolytic tolerances move the first two by 20 %; that is harmless. Use a 5 % film capacitor
for C14 and 1 % resistors for R14-R16. For 60 Hz mains, fit R16 = 15k4 and R15 = 84k5 for 17 and 83 ms.
Protective features in the logic: power-on reset (U2a) holds U1 for 0.4 s; the
pulse timer can only run inside the relay window; the opto LEDs are in series; the relay coil current
passes through the thermal switch and the cap microswitch, so nothing in the logic can override them.
The control board. Timers, comparators, SCR switch.
Limits you should know about
Pulse length is set by an RC timer, not by counting cycles. The SCRs then round it to whole half-cycles, so you get the nominal count plus or minus one half-cycle (800 ms is 80 ± about 4 half-cycles with 5 % parts). In AC mode the polarity of the first half-cycle is random.
Burst trains with a 20 ms gap are not supported. Every shot is followed by a 24 s lock-out.
A 10 Ω ballast and the transformer's own impedance limit the current to about 4.6 A at 110 V into a dead short. Matsumoto's source was probably stiffer, so the initial surge is smaller here. That is a deliberate safety trade.
The initial surge: wire depth and the supply
Beside entry S-71 in his logbook, Matsumoto noted that the effect of a long pulse is small and the effect of the initial surge is marked. Our working view is that the surge matters because it drives a shock wave in the liquid, and that this needs a high current density at the wire for a few milliseconds. In those milliseconds, before any glow, the wire and the liquid are simply a resistor, and almost all of the resistance is in the liquid right at the wire. So two things set the current density: how deep the wire sits, and how stiff the supply is. The figures here are estimates for the kit's cell as designed, in 1.5 mol/L KOH. They are not measurements.
Depth. A deeper wire draws more current in total, but less at each point of its surface.Supply. The supply sets how much of that current density reaches the wire.
Supply, 120 V AC
Tip just touching
0.5 mm deep
1 mm deep
3 mm deep
Stiff supply, no internal resistance
9.4 A/mm²
6.0 A/mm²
4.8 A/mm²
3.5 A/mm²
3 Ω supply (an example, not a chosen part)
7.9 A/mm²
4.4 A/mm²
3.3 A/mm²
1.8 A/mm²
Present kit design: 80 VA transformer and 10 Ω ballast, 26.6 Ω in all
3.6 A/mm²
1.4 A/mm²
0.9 A/mm²
0.4 A/mm²
Depth. With the tip just touching the liquid, about 7 A flows through less than one square millimetre of wire. Three millimetres deep, the current is nearly five times higher, but the current density is down to little more than a third. The kit sets the tip just touching, as in Matsumoto's sketch, because that is where the current density is highest. Below about 0.5 mm the meniscus decides the real depth, so set the tip with care and write its position down for every shot.
Supply. The present design holds the current into a short circuit to about 4.6 A, as a safety choice. With the tip just touching, that gives about 38 % of the current density of a stiff supply, and half a millimetre too deep loses more than half of it. The supply is therefore under review. A stiffer supply needs another way to limit the energy if something fails.
Others fix the depth too. International patent application WO 2015/108434 A1, “Method and device for producing thermal energy by plasma electrolysis” (Yu. N. Bazhutov, A. I. Gerasimova, V. P. Koretsky and A. G. Parkhomov; filed 16 January 2014, published 23 July 2015), specifies an anode rod of a heat-resistant metal such as tungsten, 3 to 10 mm in diameter with a sharp tip, immersed to a depth equal to its diameter. The electrolyte is held at a constant level, and more than 300 V and more than 1.0 A are applied. That is a sustained plasma on a thicker rod, not one short pulse on a 1 mm wire, so only its depth rule is used here. Its claims of excess heat and nuclear products are the applicants' own, are not accepted by mainstream physics, and are not relied on.
The film “The surge” goes through these graphs. The first test stage of the campaign will measure the surge directly.
The control board layout
One layout serves both builds. On stripboard the copper strips are the bottom layer and the wire
links are the top layer; the PCB (127 × 95 mm, 2 layers) reproduces that, with wider copper where the output current flows. A script
checks the layout against the netlist on every run, which proves the board matches the schematic,
not that the schematic is right.
Stripboard, component side.Stripboard, copper side.PCB version, same layout.
Stripboard notes that matter for safety
Cut all 36 strips at columns 38 and 39 first. That moat is the safety barrier.
The SCR tabs are live and at different potentials: no heatsinks, and they must not touch.
Use a bipolar NE555 for U1 and U3 (not a CMOS 555), and a nylon M3 × 8 screw with a nylon washer (no spacer) at the mounting hole nearest SCR1.
09
Films
Design renders: the kit has not yet been built or tested.
Everything listed below in one archive, the same for every language. Inside, documents/ holds the documents in each language, FILES.txt describes every file in each language, and an optional script adds the names in your language to the 3D files.
Version of these files: 24 November 2026. First published on 23 November 2026. The design has not been built or tested, so figures and files are corrected when an error is found. Every change made after first publication is listed here.
Changes on 25 November 2026
New section and film. How it works has a new section, “The initial surge: wire depth and the supply”, and Films has a new film, “The surge”. They give estimates of the current density at the wire against its depth and the supply, say that the supply is under review, and cite patent application WO 2015/108434 A1 for its rule on depth.
No file in Downloads has changed. The files are still the version of 24 November 2026.
Changes on 24 November 2026
Output current and the figures that follow from it. They are now calculated from the transformer maker's typical regulation of 11 %; before, 12 % was assumed. Transformer internal resistance: roughly 16.6 Ω in series (was 18 Ω) and 4.1 Ω in parallel (was 4.5 Ω). Short-circuit current: about 4.6 A at 110 V (was 4.4 A) and 4.3 A at 55 V (was 4.2 A). Most power the cell can take: about 140 W at 110 V (was 135 W) and 66 W at 55 V (was 65 W). Charge per shot: at most 3.7 C (was 3.5 C), which gives about 0.5 mL hydrogen (was 0.4 mL). Mixed gas per shot: at most about 0.7 mL (was 0.6 mL). One burst if an SCR has failed short: roughly 220-270 J (was 200-260 J). Changed on this page and in README, SAFETY and the electronics notes.
12 V supply module PSU1. The schematics and the bill of materials now give its real rating, 5 W (0.42 A). They gave 0.25 A. The part is the same.
Two films. The main film and “How it works” were made again so that the power schematic in them shows the corrected PSU1 label. Sound, narration and length are the same.
Nothing else has changed. No part, dimension, circuit, printed file or step of the procedure is different.
3D parts (STEP): every part's STEP file can be opened and reviewed in SolidCraft, the open-source modeller the parts were designed in (github.com/tangency-labs/solidcraft). Any CAD program that reads STEP will also open them. The STL files are for your printer's slicer.
Circuit board (Gerber): open the files from the Gerber archive together in KiCad's Gerber viewer, GerbView, which is free and open source (kicad.org/download), or in gerbv, also free and open source. You will see the copper, solder mask, legend and drill layers stacked.
Drawings and templates (PDF): PdfCraft (github.com/storytold/pdfcraft), or any PDF reader. Print the copper box template at 100 % and check the 50 mm bar.